Remote Door Relay
Remote Door Relay is used for absolute security for access control. In this case, the relay at the back of the iGuard is not used and the Remote Door Relay is installed inside the building.
Remote Door Relay Connection Terminal Description:
|
NO |
Door Relay's Normal Open |
|
COM |
Door Relay's Common |
|
NC |
Door Relay's Normal Close |
|
DOOR SW |
Door Switch |
|
DOOR SW |
Door Switch |
|
A- RS485 Connection |
connect to iGuard |
|
B- RS485 Connection |
connect to iGuard |
|
+12VDC |
+12VDC |
|
GND |
GND |
ID Selection Switches:
Turn eight ID selection switches on or off to select the ID number. for the Remote Relay. Each Switch represents a number and the selected ID is the sum of that number. For example, to set the ID of the relay box to 12, turn on switches No. 3 & 4. The following table shows the number of each switch:
|
Switch |
Number |
Requirement: |
|---|---|---|
|
1 2 3 4 5 6 7 8 |
1 2 4 8 16 32 64 128 |
In order to use this Remote Door Relay Board, special requirement of iGuard is necessary. 1. Firmware Version: 3.2.9987A or up (can be updated by firmware update patch), 2. iGuard Remote Door Relay hardware support. It can be verified by checking iGuard's status web page; "Remote Door Relay" will be shown in row "Other Feature". If item 2 is not satisfied, you should contact Lucky Technology to obtain a hardware upgrade. |
In terminal setup, it has to be enabled.